Slurry density changes the pressure equivalent of a stated head. Use the density of the transported mixture, define the head basis, and keep the conversion separate from pump selection and pipe approval. In solid-wall HDPE mining pipelines, confusing metres of fluid with bar can produce an incomplete pressure specification even when OD and SDR are clearly stated.
Identify which density belongs in the calculation
Mixture density includes the carrier liquid and suspended solids. Particle density describes the solid material alone; it is not automatically the density of the pumped slurry. State density in kg/m³ and identify the sampling location, operating condition and measurement method.
Specific gravity, or relative density, is a ratio and has no units. When a simplified calculation uses water density of 1000 kg/m³ as its reference, a mixture density of 1400 kg/m³ corresponds to SG 1.4. Use a consistent reference and account for entrained gas or changing composition where relevant. A single nominal value may not cover the operating envelope.
Convert a defined head to bar
For the pressure equivalent of a specified fluid head, p = ρgH. With density ρ in kg/m³, g = 9.81 m/s² and head H in metres, p in bar = ρ × 9.81 × H / 100000. One bar is 100000 Pa; 10 bar is 1 MPa.
| Head | 1000 kg/m³ | 1400 kg/m³ | 1800 kg/m³ |
|---|---|---|---|
| 20 m | 1.96 bar | 2.75 bar | 3.53 bar |
| 40 m | 3.92 bar | 5.49 bar | 7.06 bar |
| 60 m | 5.89 bar | 8.24 bar | 10.59 bar |
These hypothetical conversions do not predict a pump’s operating point or establish the pressure at every point on a route. They also do not include an additional allowance for surge. Define whether the stated head is static elevation head, pressure head or the total head added by a pump before using the result.
Do not interchange mass and volume concentration
For a simple gas-free, two-component mixture with additive volumes, density can be calculated from the constituent masses and densities. As an explicitly hypothetical example, take 1 kg of slurry containing 0.5 kg solids at 2700 kg/m³ and 0.5 kg liquid at 1000 kg/m³. Its volume is 0.5/2700 + 0.5/1000 m³, giving a mixture density of about 1459 kg/m³.
That is 50% solids by mass, not by volume. A mixture containing 50% solids by volume with the same constituent densities would instead have density 0.5 × 2700 + 0.5 × 1000 = 1850 kg/m³. Confusing the two changes the head-to-pressure calculation. Check the concentration basis on laboratory sheets and process documents rather than assuming that “50% solids” is complete.
For operating comparisons, retain density and concentration alongside slurry pipeline pressure measurements. Readings from different mixture conditions should not be diagnosed as a pipe restriction without further review.
Keep the complete system head separate from the conversion
A pumping duty can include elevation change, pressure differences at boundaries, velocity-head differences and friction losses. The pressure gain across a pump is not automatically its discharge gauge pressure: inlet conditions and the measurement elevations also matter. State gauge or absolute pressure explicitly and use the same reference throughout each calculation.
A water-test pump curve may require slurry-specific head and efficiency corrections. Density conversion does not account for particle effects, rheology, settling behaviour or changes in the operating point. Use the pump manufacturer’s applicable method and a system model for the actual slurry; do not obtain a complete slurry duty simply by multiplying a water pressure by SG.
Review normal running, flushing, shutdown, restart and credible transient conditions separately. A denser mixture at a stated head changes pressure, but the real system may also change head and flow.
Connect the pressure envelope to the actual HDPE line
SDR6, SDR7.4 and SDR9 describe wall proportions. They do not state the fluid density, pump head or an automatically approved pressure class. Establish the applicable material, standard, temperature factors and component limitations before selecting the line specification.
For 630, 710, 1000 or 1200 mm OD pipe, use the actual bore when calculating velocity and losses. At a fixed OD, a thicker wall reduces the passage. A density table does not compensate for an incorrect bore, and the resulting change in hydraulic resistance can move the operating point.
Make the calculation basis reviewable
A useful calculation sheet identifies mixture-density range, concentration basis, particle properties, temperature, flow range, elevations and pipe geometry. It also states the pump curve and correction method, boundary pressures, pressure reference and cases included. Keep calculated conversions separate from measurements and approved component ratings.
Use the resulting pressure profile when reviewing pressure-zone and pump-staging decisions. That guide provides related planning questions; a slurry duty still requires slurry-specific inputs. If the mixture data are uncertain, obtain representative measurements or testing before treating a single calculated value as the design basis.
Frequently asked questions
Is 40 m of head always about 4 bar?
Only for a fluid close to the assumed water density in this simplified conversion. At 1400 kg/m³, 40 m corresponds to about 5.49 bar. The head basis must still be defined.
Can particle SG be used as slurry SG?
Not automatically. Mixture density includes the carrier liquid and the concentration of solids. Particle density alone does not describe the complete slurry.
Does 50% solids identify the concentration completely?
No. Specify whether it is by mass or volume and identify the constituent densities. Those bases produce different mixture densities.
Can this conversion select a pump or approve SDR9 pipe?
No. Pump performance, slurry corrections, system losses, transients and the complete pipe-and-component pressure basis require separate assessment.
Technical references
Metso Slurry Pump Handbook distinguishes head from pressure and discusses slurry corrections to water-test curves. KSB: Pressure explains pressure references and measurement elevations. Neither source approves a particular Puhui pipeline duty.